| Main | |||||||
| Product Series | XMC0 | ||||||
| Product or Component Type | Definite Purpose Contactors | ||||||
| Device Short Name | XMC0-323 | ||||||
| Contactor Application | HVAC, refrigeration, heating, data processing, welding, elevators, hoist & cranes, pool, commercial spa, and food service equipment industries, etc. | ||||||
| Poles Description | 3P | ||||||
| Rated Operational Voltage [Ue] | Power circuit: ≤ 600 V AC 50/60Hz | ||||||
| Full Load Ampere [FLA] | 32 A | ||||||
| Locked Rotor Ampere [LRA] | 180 A @ 240/277 V AC;150 A @ 480 V AC;120 A @ 600 V AC | ||||||
| Resistive Ampere [RES] | 40 A | ||||||
Control Circuit Voltage [Us]
| Code | Voltage | |||||
| E | 24 V AC 50/60Hz | ||||||
| F | 110-120 V AC 50/60Hz | ||||||
| I | 208-220 V AC 50Hz 208-240 V AC 60Hz | ||||||
| L | 277 V AC 60Hz | ||||||
| N | 380-415 V AC 50Hz 440-480 V AC 60Hz | ||||||
| Main Contact Terminals |
| ||||||
| Coil Terminals | ![]() | ||||||
| Complementary | |||||||
| Maximum Horse Power Rating | 5 hp 240/277 V AC, 1phase 10 hp 240/277 V AC, 3phase 15 hp 480 V AC, 3phase 20 hp 600 V AC, 3phase | ||||||
| Pole Contact Composition | 3 NO | ||||||
| Pollution Degree | 3 | ||||||
Control Circuit Voltage Limits @ 25℃ (Cold state) | 0.8...1.1 Us: operational AC 50/60 Hz 0.2...0.75 Us: drop-out AC 50/60 Hz | ||||||
Nominal Inrushed VA @ 25℃ (Cold state) | E:55 VA @ 24V 50 Hz, 50 VA @ 24V 60Hz F:65 VA @ 120V 50 Hz, 60 VA @ 120V 60Hz I:45 VA @ 220V 50 Hz, 50 VA @ 240V 60Hz L:50 VA @ 277V 60Hz N:45 VA @ 415V 50 Hz, 60 VA @ 480V 60Hz | ||||||
Nominal Sealed VA @ 25℃ (Cold state) | E:10 VA @ 24V 50 Hz, 8 VA @ 24V 60Hz F:13.5 VA @ 120V 50 Hz, 10 VA @ 120V 60Hz I:9.5 VA @ 220V 50 Hz, 9.5 VA @ 240V 60Hz L:10.5 VA @ 277V 60Hz N:12 VA @ 415V 50 Hz, 13 VA @ 480V 60Hz | ||||||
| Maximum Operating Rate | Electrical: 360 cycs/h Mechanical: 3600 cycs/h | ||||||
| Tightening Torque | Power circuit: 25 lb-in - on screw terminals Power circuit: 25 lb-in - on box lug terminals Control circuit: 8 lb-in | ||||||
| Auxiliary Contact Composition | W/o built-in auxiliary contacts. Additional auxiliary contact modules can be installed if needed. | ||||||
| Mounting Support | Screw | ||||||
| A2L application: | Suffix w/ “W” : Flame Arrest-protected Components for Use in Refrigeration and Air-conditioning Equipment Employing A2L Refrigerants. | ||||||
| Minimum Switching Load | 110 VAC, 1A | ||||||
Environment | |||||||
| Standards | UL 60947-4-1, GB/T 14048.4, IEC 60947-4-1, EN 60947-4-1 | ||||||
| Product Certifications | UL, CCC, TÜV | ||||||
Permissible Ambient Air Temperature Around the Device | -40 °C…70 °C (-40 °F…158 °F) for normal operating -40 °C…70 °C (-40 °F…158 °F) for storage | ||||||
| Height | 95 mm | ||||||
| Width | 60.2 mm | ||||||
| Depth | 75 mm | ||||||
| Net Weight | 0.44 kg | ||||||
| Packing Units | |||||||
| Unit Type of Package (bulk package) | 1 carton | ||||||
| Number of Units in Package | 30 pcs | ||||||
| Package Height | 215 mm | ||||||
| Package Width | 340 mm | ||||||
| Package Length | 360 mm | ||||||
| Package Weight | 14.2 kg | ||||||
| Offer Sustainability | |||||||
| REACH Regulation | Conforming | ||||||
| EU RoHS Directive | Conforming | ||||||
| Mercury Free | Yes | ||||||
| China RoHS Regulation | Conforming | ||||||
| RoHS Exemption Information | Yes | ||||||
| Contractual Warranty | |||||||
| Warranty | 18 months | ||||||
Dimensions
XMC0 3P 25-40A(3NO)
AC Contactor:

Note: The unit is mm. The tolerance for mounting holes: ± 0.5; for other external dimensions: ± 1.5, unless otherwise specified.